marktsai168 發表於 2013-11-25 12:22

EddieTsai 發表於 2013-11-11 12:36 static/image/common/back.gif
手機 (S4)上的讀值如下...

很不錯的訊息
不知道有沒有油溫的ㄋ?

EddieTsai 發表於 2013-11-11 00:12

PRIUS C 冷氣系統 OBDII PIDS (Torque pro)

本帖最後由 EddieTsai 於 2013-11-11 00:18 編輯




Air Conditioner
Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note

Room Temperature Sensor
Room temperature sensor (cooler thermistor) /
Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed
-

Ambient Temp Sensor
Ambient temperature sensor (thermistor assembly) /
Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed
-

Adjusted Ambient Temp
Adjusted ambient temperature /
Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
-
-

Evaporator Fin Thermistor
Evaporator temperature sensor (No. 1 cooler thermistor) /
Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed
-

Evaporator Target Temp
Evaporator target temperature /
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed
-

Solar Sensor (D Side)
Solar sensor /
Min.: 0
Max.: 255
Solar sensor value increases as brightness increases
-

Engine Coolant Temp
Engine coolant temperature sensor /
Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
-

Set Temperature (D Side)
Set temperature /
Min.: MAX COLD
Max.: MAX HOT
Set temperature displayed
-

Blower Motor Speed Level
Blower motor speed level /
Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases
-

Regulator Pressure Sensor
Air conditioning pressure sensor /
Min.: -456.68 kPa (-66.2 psi(gauge))
Max.: 3294.37 kPa (478 psi(gauge))
Actual pressure displayed
-

Air Mix Servo Targ Pulse(D)
No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse /
Min.: 128
Max.: 383
MAX. COLD: 257 (pulse)
MAX. HOT: 173 (pulse)
-

Air Mix Servo Actual Pulse(D)
No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse /
Min.: 128
Max.: 383
MAX. COLD: 257 (pulse)
MAX. HOT: 173 (pulse)
-

Air Outlet Servo Pulse (D)
No. 2 air conditioning radiator damper servo sub-assembly (air outlet) target pulse /
Min.: 128
Max.: 383
FACE: 267 (pulse)
B/L: 250 (pulse)
FOOT: 227 (pulse)
FOOT/DEF: 220 (pulse)
DEF: 206 (pulse)
-

Air Outlet Servo Actu Pulse(D)
No. 2 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse /
Min.: 128
Max.: 383
FACE: 267 (pulse)
B/L: 250 (pulse)
FOOT: 227 (pulse)
FOOT/DEF: 220 (pulse)
DEF: 206 (pulse)
-

Air Inlet Damper Targ Pulse
No. 1 blower damper servo sub-assembly (air inlet) target pulse /
Min.: 128
Max.: 383
RECIRCULATION: 287 (pulse)
FRESH: 254 (pulse)
-

Air Inlet Damper Actual Pulse
No. 1 blower damper servo sub-assembly (air inlet) actual pulse /
Min.: 128
Max.: 383
RECIRCULATION: 287 (pulse)
FRESH: 254 (pulse)
-

Electric Heater Count*1
Maximum heater operation level /
Min.: 0
Max.: 3
Maximum possible operation level of quick heater assembly displayed
-

Electric Heater Active Level*1
Actual heater operation level /
Min.: 0
Max.: 3
Actual operation level of quick heater assembly displayed
-

Compressor Speed
Compressor speed /
Min.: 0 rpm
Max.: 65535 rpm
Actual compressor rotation speed displayed
-

Compressor Target Speed
Compressor target speed /
Min.: 0 rpm
Max.: 65535 rpm
Compressor target rotation speed displayed
-

Shift Set Temperature
Shift set temperature /
2C decr, 1C decr, Normal, 1C incr, 2C incr
Customized value displayed
-

Compressor Mode
Compressor mode /
Auto or Manual
Customized value displayed
-

Noise and Vibration Reduction
Noise and vibration reduction /
OFF or ON
Customized value displayed
-

ECO MODE Cancel
ECO MODE Cancel /
OFF or ON
Customized value displayed
-

ECO Switch
ECO mode switch (eco switch assembly) /
OFF or ON
ECO mode switch (eco switch assembly) operated: ON
(when switch is pressed)
-

ECO mode switch (eco switch assembly) not operated: OFF
(when switch is not pressed)
-

Refrigerant Shortage Check
Refrigerant shortage check /
ON or OFF
Customized value displayed
-

Fan speed increment control
Fan speed increment control /
Slow, Normal, Fast
Customized value displayed
-

Foot/DEF Auto Mode
Foot/DEF Auto Mode /
ON or OFF
Customized value displayed
-

Foot/DEF Auto Blow Up
Foot/DEF Auto blower speed increase /
ON or OFF
Customized value displayed
-

Ambient Temperature Shift
Ambient temperature shift /
3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr
Customized value displayed
-

Pls Servo Test Sts
Pulse servo motor test status/
Wait, Move, Comp, Error, Stop
Pulse servo motor test status
-

Compressor Drive Check
Compressor drive check /
OK or NG
NG: Compressor does not drive
OK: Compressor drives
-

Number of Trouble Codes
Number of trouble codes /
Min.: 0
Max.: 255
Number of DTCs displayed
-


[*]*1 w/ Quick Heater Assembly





EddieTsai 發表於 2013-11-11 00:21

續...
Name
ShortName
ModeAndPID
Equation
Min Value
Max Value
Units
Header

Room Temp Sensor
Room
2121
A * 63.75 / 255 - 6.5
-6.5
57.25
C
7C4

Ambient Temp Sensor
Ambient
2122
A * 89.25 / 255 - 23.3
-23.3
65.95
C
7C4

Solar Sensor (D side)
Solar D
2124
A
0
255

7C4

Engine Coolant Temp_7C4
Coolant_7C4
2126
A * 89.25 / 255 + 1.3
1.3
90.55
C
7C4

Set Temperature (D side)
Set t D
2129
A / 2 + 17.5
17.5
32.5
C
7C4

Blower Motor Speed Level
Blower Level
213C
A
0
31

7C4

Adjusted Ambient Temp
AdjAmbient
213D
A * 81.6 / 255 - 30.8
-30.8
50.8
C
7C4

Air Mix Servo Targ Pulse (D)
A/M STP D
2141
A + 128
128
383

7C4

Air Mix Servo Actual Pulse (D)
A/M SAP D
2141
B + 128
128
383

7C4

Air Outlet Servo Pulse (D)
A/O SP D
2143
A + 128
128
383

7C4

Air Outlet Servo Actu Pulse (D)
A/O SAP D
2143
B + 128
128
383

7C4

Air Inlet Damper Targ Pulse
A/I DTP
2144
A + 128
128
383

7C4

Air Inlet Damper Actual Pulse
A/I DAP
2144
B + 128
128
383

7C4

Compressor Speed
Comp Spd
2149
A * 256 + B
0
10000
RPM
7C4

Compressor Target Speed
Comp T Spd
214A
A * 256 + B
0
10000
RPM
7C4

Evaporator Fin Thermistor
Evap Fin
214B
A * 89.25 / 255 - 29.7
-29.7
59.55
C
7C4

Evaporator Target Temp
Evap Tgt
214C
(A * 256 + B) / 100 - 327.68
-29.7
59.55
C
7C4





EddieTsai 發表於 2013-11-11 12:36

手機 (S4)上的讀值如下...




EddieTsai 發表於 2013-11-25 14:14

有的,下星期在補上!

atek945 發表於 2013-12-14 11:11

EddieTsai 發表於 2013-11-11 12:36 static/image/common/back.gif
手機 (S4)上的讀值如下...

這九個數值…可以中文解釋嗎?

reg pres
evap tgt
evap fin
comp t spd
comp spd
set t d
adj ambient
solar D
blower level
ambient
room 室溫(只看懂這個)

EddieTsai 發表於 2013-12-14 18:09

本帖最後由 EddieTsai 於 2013-12-14 18:11 編輯

reg pres 調整壓力值
evap tgt 蒸發器目標溫度
evap fin 蒸發器温度
comp t spd 压縮机目標轉速
comp spd 压縮机轉速
set t d 設定溫度
adj ambient 户外溫度調整值
solar D 光線亮度
blower level 風扇強度
ambient 户外温度

非專業人員之翻譯,多包涵…

Arnold777 發表於 2013-12-17 21:35

好詳細……
原來可以監控這麼多……

atek945 發表於 2013-12-17 21:18

EddieTsai 發表於 2013-12-14 18:09 static/image/common/back.gif
reg pres 調整壓力值
evap tgt 蒸發器目標溫度
evap fin 蒸發器温度


翻得粉好!至少讓偶看得懂哩~

我覺得這篇很有參考意義:
一、省電就是省油,冷氣最耗電
二、調整最適當溫度,有益人體健康
三、間接調整車內濕度,也讓車體健康

atek945 發表於 2013-12-18 22:50

下雨天、冷天除霧…
要掌握哪些資訊?

待研究
頁: [1] 2
查看完整版本: PRIUS C 冷氣系統 OBDII PIDS (Torque pro)